102 research outputs found

    Tracking the Endocardial Border in Artifact-Prone 3D Images

    Get PDF
    Echocardiography is a commonly-used, safe, and noninvasive method for assessing cardiac dysfunction and related coronary artery disease. The analysis of echocardiograms, whether visual or automated, has traditionally been hampered by the presence of ultrasound artifacts, which obscure the moving myocardial wall. In this study, a novel method is proposed for tracking the endocardial surface in 3D ultrasound images. Artifacts which obscure the myocardium are detected in order to improve the quality of cardiac boundary segmentation. The expectation-maximization algorithm is applied in a stationary and dynamic, cardiac-motion frame-of-reference, and weights are derived accordingly. The weights are integrated with an optical-flow based contour tracking method, which incorporates prior knowledge via a statistical model of cardiac motion. Evaluation on 35 three-dimensional echocardiographic sequences shows that this weighed tracking method significantly improves the tracking results. In conclusion, the proposed weights are able to reduce the influence of artifacts, resulting in a more accurate quantitative analysis

    Left Ventricular Border Tracking Using Cardiac Motion Models and Optical Flow

    Get PDF
    The use of automated methods is becoming increasingly important for assessing cardiac function quantitatively and objectively. In this study, we propose a method for tracking three-dimensional (3-D) left ventricular contours. The method consists of a local optical flow tracker and a global tracker, which uses a statistical model of cardiac motion in an optical-flow formulation. We propose a combination of local and global trackers using gradient-based weights. The algorithm was tested on 35 echocardiographic sequences, with good results (surface error: 1.35 ± 0.46 mm, absolute volume error: 5.4 ± 4.8 mL). This demonstrates the method’s potential in automated tracking in clinical quality echocardiograms, facilitating the quantitative and objective assessment of cardiac functio

    Deep learning-enabled MRI-only photon and proton therapy treatment planning for paediatric abdominal tumours

    Get PDF
    Purpose: To assess the feasibility of magnetic resonance imaging (MRI)-only treatment planning for photon and proton radiotherapy in children with abdominal tumours. Materials and methods: The study was conducted on 66 paediatric patients with Wilms' tumour or neuroblastoma (age 4 +/- 2 years) who underwent MR and computed tomography (CT) acquisition on the same day as part of the clinical protocol. MRI intensities were converted to CT Hounsfield units (HU) by means of a UNet-like neural network trained to generate synthetic CT (sCT) from T1- and T2-weighted MR images. The CT-to-sCT image similarity was evaluated by computing the mean error (ME), mean absolute error (MAE), peak signal-to-noise ratio (PSNR) and Dice similarity coefficient (DSC). Synthetic CT dosimetric accuracy was verified against CT-based dose distributions for volumetric-modulated arc therapy (VMAT) and intensity-modulated pencil-beam scanning (PBS). Relative dose differences (D-diff) in the internal target volume and organs-at-risk were computed and a three-dimensional gamma analysis (2 mm, 2%) was performed. Results: The average +/- standard deviation ME was -5 +/- 12 HU, MAE was 57 +/- 12 HU, PSNR was 30.3 +/- 1. 6 dB and DSC was 76 +/- 8% for bones and 92 +/- 9% for lungs. Average D-diff were 99% (range [85; 100]%) for VMAT and >96% (range [87; 100]%) for PBS. Conclusion: The deep learning-based model generated accurate sCT from planning T1w- and T2w-MR images. Most dosimetric differences were within clinically acceptable criteria for photon and proton radiotherapy, demonstrating the feasibility of an MRI-only workflow for paediatric patients with abdominal tumours. (C) 2020 The Authors. Published by Elsevier B.V

    Exploring label dynamics of velocity-selective arterial spin labeling in the kidney

    Get PDF
    Purpose: Velocity-selective arterial spin labeling (VSASL) has been proposed for renal perfusion imaging to mitigate planning challenges and effects of arterial transit time (ATT) uncertainties. In VSASL, label generation may shift in the vascular tree as a function of cutoff velocity. Here, we investigate label dynamics and especially the ATT of renal VSASL and compared it with a spatially selective pulsed arterial spin labeling technique, flow alternating inversion recovery (FAIR). Methods: Arterial spin labeling data were acquired in 7 subjects, using free-breathing dual VSASL and FAIR with five postlabeling delays: 400, 800, 1200, 2000, and 2600 ms. The VSASL measurements were acquired with cutoff velocities of 5, 10, and 15 cm/s, with anterior–posterior velocity-encoding direction. Cortical perfusion-weighted signal, temporal SNR, quantified renal blood flow, and arterial transit time were reported. Results: In contrast to FAIR, renal VSASL already showed fairly high signal at the earliest postlabeling delays, for all cutoff velocities. The highest VSASL signal and temporal SNR was obtained with a cutoff velocity of 10 cm/s at postlabeling delay = 800 ms, which was earlier than for FAIR at 1200 ms. Fitted ATT on VSASL was ≤ 0 ms, indicating ATT insensitivity, which was shorter than for FAIR (189 ± 79 ms, P .05) with good correlations on subject level. Conclusion: Velocity-selective arterial spin labeling in the kidney reduces ATT sensitivity compared with the recommended pulsed arterial spin labeling method, as well as if cutoff velocity is increased to reduce spurious labeling due to motion. Thus, VSASL has potential as a method for time-efficient, single-time-point, free-breathing renal perfusion measurements, despite lower tSNR than FAIR

    Predicting clinical benefit from everolimus in patients with advanced solid tumors, the CPCT-03 study

    Get PDF
    Background: In this study, our aim was to identify molecular aberrations predictive for response to everolimus, an mTOR inhibitor, regardless of tumor type. Methods: To generate hypotheses about potential markers for sensitivity to mTOR inhibition, drug sensitivity and genomic profiles of 835 cell lines were analyzed. Subsequently, a multicenter study was conducted. Patients with advanced solid tumors lacking standard of care treatment options were included and underwent a pre-treatment tumor biopsy to enable DNA sequencing of 1,977 genes, derive copy number profiles and determine activation status of pS6 and pERK. Treatment benefit was determined according to TTP ratio and RECIST. We tested for associations between treatment benefit and single molecular aberrations, clusters of aberrations and pathway perturbation. Results: Cell line screens indicated several genes, such as PTEN (P = 0.016; Wald test), to be associated with sensitivity to mTOR inhibition. Subsequently 73 patients were included, of which 59 started treatment with everolimus. Response and molecular data were available from 43 patients. PTEN aberrations, i.e. copy number loss or mutation, were associated with treatment benefit (P = 0.046; Fisher's exact test). Conclusion: Loss-of-function aberrations in PTEN potentially represent a tumor type agnostic biomarker for benefit from everolimus and warrants further confirmation in subsequent studies

    Simultaneous multiresolution strategies for nonrigid image registration

    No full text
    Multiresolution strategies are commonly used in the nonrigid registration to avoid local minima in the optimization space. Generally, a step-by-step hierarchical approach is adopted, in which the registration starts on a level with reduced complexity (downsampled images, global transformations), then continuing to levels with increased complexity, until the finest level is reached. In this paper, we propose two alternative multiresolution strategies for both the data and transformation models, in which different resolution levels are considered simultaneously instead of subsequently. Through combining the different strategies for data and transformation, we systematically define 3Ă—3 multiresolution schemes, including both existing and novel methods. Experiments on 10 pairs of computed tomography lung data sets showed that the best performing strategy resulted in a reduction of the upper quartile of the mean target registration error from 2 to 1.5 mm, compared with the conventionally hierarchical multiresolution method, while achieving smoother deformations. Experiments with intersubject registration of 18 3D T1-weighted MRI brain scans confirmed that simultaneous multiresolution strategies produce more accurate registration results (median of mean overlap increased from 0.55 to 0.57) and smoother deformation fields than the traditionally hierarchical method. Evaluation of robustness indicated that the largest differences in accuracy between methods are observed for structures with a relatively large initial misalignment

    Perfusion imaging of neuroblastoma and nephroblastoma in a paediatric population using pseudo-continuous arterial spin-labelling magnetic resonance imaging

    Get PDF
    Objectives To examine the feasibility of performing ASL-MRI in paediatric patients with solid abdominal tumours. Methods Multi-delay ASL data sets were acquired in ten paediatric patients diagnosed with either a neuroblastoma (n = 4) or nephroblastoma (n = 6) during a diagnostic MRI examination at a single visit (n = 4 at initial staging, n = 2 neuroblastoma and n = 2 nephroblastoma patients; n = 6 during follow-up, n = 2 neuroblastoma and n = 4 nephroblastoma patients). Visual evaluation and region-of-interest (ROI) analyses were performed on the processed perfusion-weighted images to assess ASL perfusion signal dynamics in the whole tumour, contralateral kidney, and tumour sub-regions with/without contrast enhancement. Results The majority of the included abdominal tumours presented with relatively low perfusion-weighted signal (PWS), especially compared with the highly perfused kidneys. Within the tumours, regions with high PWS were observed which, at short PLD, are possibly related to labelled blood inside vessels and at long PLD, reflect labelled blood accumulating inside tumour tissue over time. Conversely, comparison of ASL perfusion-weighted image findings with T(1)w enhancement after contrast administration showed that regions lacking contrast enhancement also were void of PWS. Discussion This pilot study demonstrates the feasibility of utilizing ASL-MRI in paediatric patients with solid abdominal tumours and provides a basis for further research on non-invasive perfusion measurements in this study population
    • …
    corecore